Orion Star T930 ion titrator without electrode

Orion Star T930 ion titrator without electrode

Orion Star T930 ion titrator without electrode

4220 In stock
P/N: START9300
€4,220.00
€4,220.00
OR
OR
Application: 

designed for liquid handling in laboratory

Set includes: 

Orion Star T930 ion titrator without electrode, includes 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L, plastic bottle, GL38 bottle cap with drying tube, computer cable, literature on USB flash drive, 110 ÷ 240V power supplies

Display: 

5.7” color capacitive touchscreen, 640 x 480 resolution, with adjustable backlight and lab glove compatibility

Titration technique:

equivalence point (1 or 2)  or preset endpoint (1, 2 or 3)

MKA points: 

up to 5

Titration types: 

direct or back titration

Blank options: 

fixed value or variable value using titration

Cycles per titration run: 

up to 5 cycles per sample

Titrant determination: 

standardization titration or manual concentration input

Titration process control: 

routine, quick, careful or user defined

Titration Precision:

±0.5 % RSD

Stirrer probe speeds:  250 ÷ 3700 RPM, 5 selectable speeds
Sample ID:  auto-incremental, manual or off
Customizable methods: up to 10 methods
Burette size:  10 mL, 20 mL (included), 50 mL
Burette resolution:  25,600 micro-steps per motor revolution - 2 million micro-steps over full burette stroke range
Burette dosing accuracy standard:  ISO8655-3 requirements
Burette function:  automatic rinse cycles for flushing and discrete dispense volume with continuous option
mV range:  -2000.0 ÷ 2000.0mV
mV resolution:  0.1mV
mV accuracy:  ±0.2mV
ISE range:  0.0001 ÷ 19990
ISE resolution:  0.0001
ISE accuracy:  ±0.2 mV or ±0.05% of reading
Temperature range:  -5.0 ÷ 100.0°C; 23.0 ÷ 212°F
Temperature resolution:  0.1 °C; 0.1 °F
Temperature accuracy:  ±0.2°C
Calibration mode:  1 ÷ 5 point ion
Temperature input:  manual or automatic with optional 1 point ATC probe offset calibration
Audible notification:  titration cycle complete
maximum titrant volume
data log full
calibration due
maintenance reminder
Time and date:  yes, with nonvolatile battery backup
Communication:  import/export via USB flash drive, summary to computer software or compact printer
Data Logs:  sample titration, titrant standardization, calibration, direct measure – 100 data sets each
Data Log Export:  CSV or Report (PDF) file
Power supply:  100 ÷ 240VAC
Dimensions (L x W x H):  25.4 x 40.6 x 35.6cm
Weight:  5.67kg
Warranty:  1 year

Orion Star T930 Ion Titrator Sets 

Accessories and Consumables

ORP / Redox Electrodes and Solutions

Ion Selective Electrodes (ISE) and Solutions