Orion Star T930 ion titrator ammonia multiple known addition (MKA) kit

Orion Star T930 ion titrator ammonia multiple known addition (MKA) kit

Orion Star T930 ion titrator ammonia multiple known addition (MKA) kit

4610 In stock
P/N: START9304
€4,610.00
€4,610.00
OR
OR
Application: 

designed for liquid handling in laboratory

Set includes: 

Orion Star T930 ion titrator ammonia multiple known addition (MKA) kit, includes 9512HPBNWP high perfomance ammonia electrode, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L, plastic bottle, GL38 bottle cap with drying tube, pint bottle cap, computer cable, literature on USB flash drive, 110 ÷ 240V power supplies

Display: 

5.7” color capacitive touchscreen, 640 x 480 resolution, with adjustable backlight and lab glove compatibility

Titration technique:

equivalence point (1 or 2)  or preset endpoint (1, 2 or 3)

MKA points: 

up to 5

Titration types: 

direct or back titration

Blank options: 

fixed value or variable value using titration

Cycles per titration run: 

up to 5 cycles per sample

Titrant determination: 

standardization titration or manual concentration input

Titration process control: 

routine, quick, careful or user defined

Titration Precision:

±0.5 % RSD

Stirrer probe speeds:  250 ÷ 3700 RPM, 5 selectable speeds
Sample ID:  auto-incremental, manual or off
Customizable methods: up to 10 methods
Burette size:  10 mL, 20 mL (included), 50 mL
Burette resolution:  25,600 micro-steps per motor revolution - 2 million micro-steps over full burette stroke range
Burette dosing accuracy standard:  ISO8655-3 requirements
Burette function:  automatic rinse cycles for flushing and discrete dispense volume with continuous option
mV range:  -2000.0 ÷ 2000.0mV
mV resolution:  0.1mV
mV accuracy:  ±0.2mV
ISE range:  0.0001 ÷ 19990
ISE resolution:  0.0001
ISE accuracy:  ±0.2 mV or ±0.05% of reading
Temperature range:  -5.0 ÷ 100.0°C; 23.0 ÷ 212°F
Temperature resolution:  0.1 °C; 0.1 °F
Temperature accuracy:  ±0.2°C
Calibration mode:  1 ÷ 5 point ion
Temperature input:  manual or automatic with optional 1 point ATC probe offset calibration
Audible notification:  titration cycle complete
maximum titrant volume
data log full
calibration due
maintenance reminder
Time and date:  yes, with nonvolatile battery backup
Communication:  import/export via USB flash drive, summary to computer software or compact printer
Data Logs:  sample titration, titrant standardization, calibration, direct measure – 100 data sets each
Data Log Export:  CSV or Report (PDF) file
Power supply:  100 ÷ 240VAC
Dimensions (L x W x H):  25.4 x 40.6 x 35.6cm
Weight:  5.67kg
Warranty:  1 year

Accessories and Consumables

ORP / Redox Electrodes and Solutions

Ion Selective Electrodes (ISE) and Solutions